PROGRAMMING THE UNIT
If you are enrolling this device on a LYNXR-Series
control panel refer to the *56 Enhanced Zone
Programming Mode section in the LYNXR Installation
Guide for programming information.
Once you have selected an operating mode you must
enroll the transmitter in the control panel. When
programming the transmitter in the control panel, note
that you must program a separate zone for each loop you
are using on the transmitter. To program:
enroll the transmitter in the control panel. When
programming the transmitter in the control panel, note
that you must program a separate zone for each loop you
are using on the transmitter. To program:
1. Enter the control’s Zone Programming mode.
2. Enter the zone number to be programmed.
If the asset being protected should not be moved (i.e.,
a painting) it can be programmed as a 24 hour zone
type. If the asset will occasionally be moved, when the
system is disarmed, it can be programmed as a
perimeter zone type .
3. When prompted, enter zone type.
4. When prompted, enter Input Type 03 (3 on some
controls) – Supervised RF Transmitter.
5. When prompted for the serial number, transmit from
the detector by pressing the tamper switch.
6. When the serial number is displayed, transmit from
the detector again by pressing the tamper switch.
The current loop number (4) will begin to flash.
7. Manually change the loop number to the desired loop
number for the zone (according to the application—
see Table 1).
see Table 1).
8. If you are enrolling this device on a Vista-series
control, press the * key to skip the confirmation
screen.
screen.
9. Exit Programming mode when programming is
complete, and test the detector. Refer to the Testing
section.
section.
MOUNTING
1. Replace the adhesive when relocating the device.
2. Ideal application temperature range of the tape is
2. Ideal application temperature range of the tape is
70-100°F (21-38°C). Initial tape application to
surfaces below the suggested minimum
temperature is not recommended because the
adhesive becomes too firm to adhere readily.
adhesive becomes too firm to adhere readily.
The 5870API can be permanently or temporarily mounted
directly to the asset to be protected via 3M VHB double-
sided tape or removable adhesive double-sided tape. Two
types of tape are provided with the device and the
selections should be based on the end use environment
and conditions. Once cured the black tape (with red
directly to the asset to be protected via 3M VHB double-
sided tape or removable adhesive double-sided tape. Two
types of tape are provided with the device and the
selections should be based on the end use environment
and conditions. Once cured the black tape (with red
release liner) has a stronger bond, except in low
temperature applications where the gray tape should be
used.
temperature applications where the gray tape should be
used.
1. Determine the optimum mounting location taking care
to avoid damp locations. To maximize the
transmitter’s range avoid mounting the device to
metal objects, if possible.
transmitter’s range avoid mounting the device to
metal objects, if possible.
2. Temporarily mount the device to the asset to be
protected using masking tape or any suitable method.
3. Before the transmitter is permanently mounted,
conduct Go/No Go tests (refer to the Control Panel’s
instructions) to verify adequate signal strength from
the mounting location.
instructions) to verify adequate signal strength from
the mounting location.
4. Always verify range by holding the sensor in the
approximate mounting location and moving the asset.
The panel (in test mode) should respond to the
transmissions. If not, find a more suitable mounting
location.
The panel (in test mode) should respond to the
transmissions. If not, find a more suitable mounting
location.
5. If your application (“permanent”) requires the black
tape, remove the gray tape. Clean any fingerprints
and adhesive residue and install the black tape on the
sensor.
and adhesive residue and install the black tape on the
sensor.
Take care to align the hole in the tape with the
device’s tamper switch plunger.
6. Clean the area, where the sensor will be mounted,
with a mixture of water and isopropyl alcohol.
To obtain proper performance with all 3M VHB tapes,
it is important to ensure that the surfaces are dry and
free of condensed moisture.
7. Once the surface has been cleaned, remove the tape
backing paper and firmly press the sensor in the
desired mounting location. Apply pressure for 30
seconds.
desired mounting location. Apply pressure for 30
seconds.
Firm application pressure develops better adhesive
contact and helps improve bond strength. After
application, the bond strength will increase. At room
temperature approximately 50% of ultimate bond
strength will be achieved after 20 minutes, 90% after
24 hours and 100% after 72 hours.
8. Verify operation by moving the asset. Always check
the alarm panel keypad to verify that the zone has
tripped.
tripped.
REPLACING THE BATTERY
A 3-volt lithium battery powers the 5870API. If the
battery voltage gets too low, the device sends a low battery
signal to the control panel.
battery voltage gets too low, the device sends a low battery
signal to the control panel.
The 5870API consume less battery power when stationary
than when in motion. Maximum battery life will be
obtained when used on assets that are moved infrequently
(e.g.; televisions, paintings, sculpture, etc.)
than when in motion. Maximum battery life will be
obtained when used on assets that are moved infrequently
(e.g.; televisions, paintings, sculpture, etc.)
Replace the battery with Ademco 469, Sanyo CR2,
Panasonic CR2 or Duracell DLCR2. Use of another
battery may present the risk of fire or explosion
1. Using a screwdriver, release the case’s retaining tabs.
2. Carefully remove the sensor’s cover. (see Figure 2)