NX-1700E Card Reader
12
L
OCATION
244
P
ROGRAMMING THE
V
ARIOUS
R
EADER
T
IMERS
(3 segment of numerical data)
Segment 1
2 Scan Hold Time
Enter the amount of time allowed for a double scan to be detected and the amount of time required to
hold a card to activate the functions programmed in Location 0, Segments 2 and 3. This timer is timed in
1/100 second increments from 0 to 2.55 seconds. (Default is 75 = ¾ second).
Segment 2
Relay Active Time
Enter the amount of time the Relay Driver is energized once activated. This timer is timed in 1/10 second
increments from 0 to 25.5 seconds. (Default is 50 = 5 seconds).
Segment 3
Door Prop Time
Enter the amount of time a monitored zone (see Location 243) must be faulted before sounding an alarm
(local buzzer). This timer is timed in 1-second increments from 0 to 255 seconds. (Default is 10 = 10
seconds).
L
OCATION
245
R
ESETTING THE
R
EADER
A
DDRESS
(1 segment of numerical data) If it is necessary to reset the address of the reader, enter a 0 in this
location.
This will cause the reader to cease functioning. If a card is scanned with the system in
Program Mode, the reader will again find an available address and set itself, beeping back
to the user the address that was found as per the table on page 6. If the system is not in
Program Mode and a card is scanned at a reader with a reset address, then it will sound
an error beep.