RF Output
The versions CARRY-CODER II are available for specific frequencies. Please refer to the CARRY-CODER II serial ID for
information on the operating frequency for the unit.
CARRY-CODER II FREQUENCY VERSION
S-Band
C-Band
Frequency Range
1.99 to 2.50 GHz
4.4 -4.7 GHz
4.7-5.0 GHz
6.425-6.25 GHz
Channel
Bandwidth
Bandwidth
8/7/6 MHz
6/7/8 MHz
6/7/8 MHz
6/7/8 MHz
Format
COFDM (2K carriers)
COFDM (2K carriers)
COFDM (2K carriers)
COFDM (2K carriers)
Standard
ETS 300 744 (DVB-T)
ETS 300 744 (DVB-T)
ETS 300 744 (DVB-T)
ETS 300 744 (DVB-T)
Output Power
50 mW, 100 mW, 250 mW
and 1W (selectable)
and 1W (selectable)
10 mW, 25 mW, 100 mW
and 400 mW
and 400 mW
10 mW, 25 mW, 100 mW
and 400 mW
and 400 mW
7 mW, 15 mW, 62 mW
and 250 mW
and 250 mW
Shoulders at +/-
4.2 MHz
4.2 MHz
> 30 dB for 1W
> 35 dB for 250 mW or less
> 30 dB for 1W
> 35 dB for 250 mW or less
> 30 dB for 1W
> 35 dB for 250 mW or less
> 30 dB for 1W
> 35 dB for 250 mW or less
Harmonic and
Spurious
Spurious
< -60 dBc (DC to 6 GHz)
< -60 dBc (DC to 6 GHz)
< -60 dBc (DC to 6 GHz)
< -60 dBc (DC to 6 GHz)
In-Band Ripple
< +/- 1dB
< +/- 1dB
< +/- 1dB
< +/- 1dB
Return Loss
18 dB (typical)
18 dB (typical)
18 dB (typical)
18 dB (typical)
Impedance
50 Ohms
50 Ohms
50 Ohms
50 Ohms
Connector
N - Female
N - Female
N - Female
N - Female
Never use the CARRY-CODER II without a 50 Ohms load or antenna properly connected to the RF output, since this
could damage the RF output stage.
could damage the RF output stage.
The system can operate with several COFDM signals located on 8 MHz adjacent channels. When analog
transmissions are active in-band it is recommended to leave a free 8 MHz channel between COFDM signals and the
active analog signals.
transmissions are active in-band it is recommended to leave a free 8 MHz channel between COFDM signals and the
active analog signals.
Power Supply Input
The CARRY-CODER II can be powered either with a battery pack or through the 4 pin connector. This enables the use of an
external power source such as a battery belt or any appropriate power supply (+11 to 32 VDC @ 4A).