Справочник Пользователя для OMG plc VICP1

Скачать
Страница из 45
Origin 
Setup & 
Maintenance 
Guide 
Vicon Motion Systems Ltd.
04-Sep-2018
Page 14 of 45
Turn on clusters and pair with a Beacon
1. On the cluster, press the power button to turn it on. (Note that it is 
easiest to match physical labels with entries in the System tab if you 
turn on clusters one at a time.)
The cluster automatically searches for a radio channel with a Beacon 
pairing broadcast. It records the radio channel for communication with 
this Beacon. This record persists when the cluster is turned off.
In Evoke, on the System tab, in the Active Cluster section, a Cluster 
entry is displayed.
2. Ensure that the cluster connection status is blue (connected but not 
programmed with a marker pattern).
<img>
 
Note that the cluster battery level is indicated by status icon.
<img>
 
If any other icon is displayed, see 
 t
troubleshoot possible issues.
3. Assign a tracking object (LED pattern) to the cluster. To do this, on the 
System tab, select a cluster and from the Pattern drop-down menu, 
choose the corresponding object pattern.
Note that a cluster can be assigned a pattern from any object, but to 
avoid confusion it is best to label clusters according to their intended 
location (e.g. Green_Hand_L or Red_Backpack_Top) and name objects 
accordingly.
When you have assigned a pattern to the cluster:
• The pattern error icon clears from cluster entry.
• The cluster connection status turns green (active with LEDs turned 
on).
4. To confirm that the object is tracked and labeled correctly, check that 
in the 3D Scene view, the object model is drawn and its label matches 
the associated cluster(s).
5. When you have paired all the clusters, turn off pairing mode. To do this, 
on the System tab select Beacon and set Pairing Mode to Off.
Cluster settings are stored in the System file (by default located at 
C:
\Users\Public\Documents\Vicon\Evoke1.0\LastRun\
<username>
\LastRu
n.System
). Object settings are stored in the Subjects file (by default 
located at 
C:
\Users\Public\Documents\Vicon\Evoke1.0\LastRun\
<username>
\LastRu
n.Subjects
). Settings are auto-saved on exit.
DRAFT