Справочник Пользователя для OMG plc VICP1
Origin
Setup &
Maintenance
Guide
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd.
04-Sep-2018
Page 40 of 45
Specific Absorption Rate (SAR) certification
For United States of American Customers (FCC)
For Standalone SAR exclusion consideration, when SAR Exclusion
Threshold requirement in KDB 447498 is satisfied, standalone SAR
evaluation for general population exposure conditions by measurement or
numerical simulation is not required. At 2480 MHz, equivalent isotropically
radiated power of the devices is 3.9 mW, which will be less than the SAR
Exclusion Threshold (95.54 mW). For further information, please see clause
4.3 of KDB 447498 D01 General RF Exposure Guidance.
This device has been granted authorization to be used in the United States
for all equipment exhibiting DMR IMUAP1.
For Canadian Customers (ISED)
SAR evaluation is required if the separation distance between the user and/
or bystander and the antenna and/or radiating element of the device is less
than or equal to 20 cm, except when the device operates at or below the
applicable output power level (adjusted for tune-up tolerance) for the
specified separation distance. At 2440 MHz, equivalent isotropically
radiated power of the device is 4.1 mW, which will be less than the SAR
Exclusion Threshold at distances of between ≥5 and ≤ 10 mm of 4-7 mW
respectively at 2450 MHz. The minimum distance between the cluster
aerial and the underside is 6.69 mm. The Beacon emissions are assessed as
presenting a negligible risk. For further information, please see clause 2.5.1
of RSS-102 Issue 5 March 2015.
This device has been granted authorisation to be used in Canada for all
equipment exhibiting 11323A-IMUAP1.
For European Union Customers (RED)
Minimum safe distance for RF exposure, based on the
Reference Levels for
General Public exposure of EU Council Recommendation (1999/519/EC)
of
12 July 1999 on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz) was calculated:
Frequency
(MHz)
(MHz)
EIRP
(dBm)
(dBm)
Limit (W/
m2)
m2)
Minimum safe distance (m)
2480
6.8
10
0.0062
DRAFT