Справочник Пользователя для Checkpoint Systems Inc. EVOLVEF10

Скачать
Страница из 71
F10 Installation Manual 
                         Rev. *60          
 
50 of 71
 
•  Enable SAM:  This option button allows SAM to be Enabled (checked) or Disabled 
(unchecked).  
•  Enable Sweeper Immunity: Select this option if a sweeper is nearby and affecting the 
board's detection. During installation leave this option off until the system is tuned so that 
that DMS A view will accurately show any interfering noise characteristics.  Once the 
system has been tuned, this option can be set. 
•  Enable Noise Immunity:  Select this option if there is Environmental noise causing false 
alarms.  This option will decrease the sensitivity of the system in order to reduce the false 
alarms.  
   Note: To enable an item, check the box before it. Only checked items will be set when Apply is clicked. 
5.  Select the Options check box, then click Option 00 to enable SAM.  
 
6.  If the environmental conditions require, select options 08 or 09. Refer to Chapter 6: F10 
Tuning in order to determine if either or both of these options should be selected. 
 
a.  After selecting the required options, click Apply to enable the features. 
 
b.  A prompt appears that confirms that the smart alarm parameters were successfully set. 
Click OK; this completes the configuration of this portion of SAM. 
Changing the Patterns 
The second tab within the SAM screen is “Patterns.” Custom alarm events are configured here. 
7.  Select the Alarm Patterns checkbox to enable the pattern options. There are five (5) 
configurable parameters designed to meet the customer’s alarm response requirements: 
•  Alarm: choose from light or sounder alarms.  
•  Priority: choose from a high or low priority signal.  
•  Beep Pattern: choose from a short, medium, long, steady, quick, very short, 2-beep, 
3-beep, 4-beep, silent, *L (one short beep, one long beep), **L (two short beeps and 
one long beep) beep pattern. 
•  Duration: choose how long (in seconds) the alarm either lights or sounds for each 
alarm event.  
•  Intensity: select the intensity (volume - sound) of an alarm event.  
   Note: If the alarm duration is set to 31, the pedestal will alarm continuously.