MAINTENANCE MANUAL
965-1696
Table 6. Module and Assembly Designations (Cont)
PN
Module/Assembly
722-4446-002
Front panel module
722-4576-003
DC to DC converter
722-4577-005
Power supply output module
722-4600-004
Rear interconnect module
722-4767-001
Power supply input module
727-0008-001
RF transceiver assembly
965-1696-051
Final assembly
Figure 3. (Sheet 1 of 1) Module and Assembly Locations (GRAPHIC 23-20-59-99B-806-A01)
(2)
Electrical Description
(a)
The RTA-50D VDR provides high-speed data link communications as well as voice and
data modes. The RTA-50D VDR can provide for future Mode 3 operation which requires
digital voice and data transmission at the same time, or Mode 4 data link only.
(b)
When in voice mode, the RTA-50D VDR provides both 25-kHz and 8.33-kHz channel
spacing to meet European airspace requirements. The unit can be interchanged
with older ARINC 716 communications equipment such as the former AlliedSignal or
Bendix RTA-44A, RTA-44D, and RTA-83B VHF radios, and Collins VHF 700 and VHF
700A radios.
EFFECTIVITY
ALL
23-20-59
Page 11
1 Mar 2011
© Honeywell International Inc. Do not copy without express permission of Honeywell.