MAINTENANCE MANUAL
965-1696
Table 1001. Front Panel Functional Self-Test Results (Cont)
Mode
RTA-50D
Power
VDR
Status
Control
Fault
Antenna
Fault
Reported
Condition
Possible
Corrective
Action
Comment
Internal
fault
On
Amber
Off or
Amber
Off or
Amber
LRU reports
internal
malfunction
1. Press
functional
self-test
button
2. If condition
repeats,
reapply
power to LRU
3. If condition
repeats,
remove LRU
LRU has
detected
internal
malfunction
Internal
fault
On
Off
Off or
Amber
Off or
Amber
LRU reports
internal
malfunction
1. Press
functional
self-test
button
2. If condition
repeats,
reapply
power to LRU
3. If condition
repeats,
remove LRU
LRU has
detected
internal
malfunction
NOTES:
1
Only remove LRU if both RTP ports and both CMC ports are known to be connected and operating at
time of fault inspection.
2
Only remove LRU if antenna is known to be good and antenna connection is verified to be good at time of
fault inspection.
D.
Job Close-up (Subtask 23-20-59-810-004-A01)
(1)
Not applicable.
EFFECTIVITY
ALL
23-20-59
Page 1005
1 Mar 2011
© Honeywell International Inc. Do not copy without express permission of Honeywell.