Chapter 3 - Operation and AdministrationMonitor Program
Chapter 3: Operation and Administration
Monitor Program
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
46
3.2
Monitor Program
3.2.1
Accessing the Monitor Program
To access the Monitor program using Telnet:
1
Via the Local Management interface:
Direct local management using the Monitor program can be performed via the Local Management interface. The 
default local management IP address is 172.31.0.1, and the default Subnet Mask for this address is 255.255.255.0.
The PC used for accessing the Monitor program should be set to IP address 172.31.0.4 or any other address in the 
range 172.31.0.4–172.31.0.254.
Connect the PC to the Ethernet port used for Local Management. In the current release, the Local Management 
interface is always on the DAT3 port.
Run the Telnet program connecting to IP address 172.31.0.1.
The Enter the password message is displayed. Enter the password and press the Enter key to get to the Main menu. 
The default password is installer.
2
Via the External Management interface:
Management using either SNMP or the Monitor program can also be performed via the External Management 
interface. For details about the connectivity parameters of this interface, refer to 
 for details about the Ethernet port used for the External Management interface.
Connection of the applicable Ethernet port to the remote management device should typically be performed via a 
network device configured to support the External Management interface VLAN ID (the default is 12). 
If the PC is connected to the Ethernet port of the unit via a switching device, the IP address of the PC should be set 
to an address in the subnet of the External Management interface. The default is IP address 192.168.1.1 and Subnet 
Mask 255.255.255.0.
If access is via a routing device, configure the Next Hop Gateway parameter of the External Management interface 
(the default is 0.0.0.0, meaning none) to a valid value (in the subnet of the External Management interface). Set the 
IP address of the routing device’s port connected to the unit to the address of the Next Hop Gateway. Set the IP 
address of the PC according to the IP configuration of the relevant routing device’s port.
To manage the BreezeCOMPACT from an external network, configure the SNMP trap manager to enable 
auto-routing to the remote PC. 
Run the Telnet program connecting to the IP address of the External Management interface.
The Enter the password message is displayed. Enter the password and press the Enter key to get to the Main menu. 
The default password is installer.