Справочник Пользователя для Raytheon Anschuetz GmbH High Seas Products MTX5

Скачать
Страница из 52
28
Pathfinder Radar Scanners
The open arrray scanner has a power switch fitted to the pedestal. This switch
can normally be left ON. However, if the scanner is being serviced or if any
personnel are in the vicinity of the open array, the switch should be set to OFF.
Scanner connection
The inter-unit cable is connected to the scanner as described in Sections 2.1 and
2.2
. If you are using an inter-unit extension cable, connect this to the display
unit, and connect the supplied cable to the extension cable. The scanner
connector pins  are shown in the following diagram, together with the
connections and core colours.
CAUTION
The display connector on the inter-unit cable is a moulded plug that
cannot be replaced. DO NOT remove this moulded plug.
1
2
3
5
4
7
10
11
8
6
9
13
12
White
Black
Orange
Black
Black
Green
Yellow
Shield
Red
Red
Violet
Blue
Grey
Video
Video RTN
*Battery --ve
Tx Trigger +
Battery --ve
Data I/O +
Tx Trigger --    
Battery +ve
Data I/O --
*Battery +ve
Azimuth +
Azimuth -- 
1
2
3
4
5
6
7    
8
9
10
11
12
13
White
Black
Orange
Yellow
Green
Blue
Violet    
Grey
Red
Red
Black
Black 
8
7
6
5
4
3
2    
1
Video
Video Rtn
Tx Trigger +
Tx Trigger --
Data I/O +
Data I/O --
Azimuth +    
Azimuth --
Battery +ve
*Battery +ve
*Battery --ve
Battery --ve 
Not fitted 
on Open Array Scanners
(refer to Section 2.2)
D4290-2
Front view of
Display Cable Connector
Front view of Radome
Scanner Cable Connector
1
3
5
7
Display
Scanner
* Not present on 'light', 11 core cables.   
Battery +ve/--ve = 12 or 24v.
154_2c2.p65
13/05/99, 13:18
28