Справочник Пользователя для E F Johnson Company 2425770
7-6
Viking Portable 600 Radio Operating Manual
Messages
Table 7.2 Viking LED Failure Codes
Orange
LED
Blinks
LED
Blinks
Startup Failure
Description
2
Bad File Format
The parameter file has a newer file format version than what
matches the software in the radio.
3
Parms Fail
There is no parameter file in the radio.
4
Bad Band
The radio band in the parameter file does not match the radio band in
the tuning parameters. You will see this message if a parameter file
for the wrong band is downloaded to the radio.
5
Corrupt Parms
The parameters checksum or other data is corrupted.
6
EEPROM Fail
The self test timed out and the parameter file has not yet been read
and verified.
7
DSP Fail
This error indicates that the DSP failed to complete its startup
procedure at powerup.
8
RX Backend Fail
There is a communication failure between the DSP and the back end
ADC on the RF deck.
9
HC08 Init Fail
The HCO8 was not initialized correctly and cannot be accessed for
flash reads and writes, etc.
10
Channel Fail
The radio has been programmed with more channels than it optioned
for.
11
Encryption Fail
This error indicates that the main processor and the encryption
module have failed to complete their startup procedure at powerup.
12
Bad ESN
This error indicates that the ESN of the radio is not valid. This error is
usually only seen in the factory when first programming brand new
logic boards.
Preliminary Draft 3/9/12