MAXSK 
Set/Query maxima TCP connection 
EPHY 
Open/Close ETH interface 
RELD 
Restore to factory default setting 
Z Re-start 
module 
MID 
Query module ID information 
VER Query 
module 
software version information 
H Help 
 
Notes: HF-A11x module can works as AP or STA, user have to use different AT+ Instruction to 
set WiFi parameters when module works as AP or STA mode. 
4.2.2.1. AT+E 
„  Function: Open/Close show back function; 
„ Format: 
 
AT+E<CR> 
 
 
+ok<CR>< LF ><CR>< LF > 
 
When HF-A11x module firstly switch from transparent transmission to configuration mode, show 
back status is open, input “AT+E” to close show back function, input“AT+E” again to open show 
back function. 
4.2.2.2. AT+ENTM 
„  Function: Set module into transparent transmition mode; 
„ Format: 
 
 
 
AT+ENTM<CR> 
 
 
+ok<CR>< LF ><CR>< LF > 
 
When operate this command, module switch from configuration mode to transparent transmission 
mode.  
4.2.2.3. AT+NETP 
„  Function: Set/Query network protocol parameters; 
„ Format: 
‹ Query 
Operation 
         
AT+NETP<CR>
 
  
 
+ok=<protocol,CS,port,IP><CR>< LF ><CR>< LF >
 
‹ Set 
Operation 
AT+NETP=<protocol,CS,port,IP><CR> 
  
 
+ok<CR>< LF ><CR>< LF >
 
„ Parameters: 
‹ protocol: 
— TCP 
— UDP 
‹  CS: Network mode: 
— SERVER 
— CLIENT 
‹  Port: protocol port ID: Decimal digit and less than 65535 
‹  IP: Server’s IP address when module set as client 
After HF-A11x module boots up again, the setting will be effective.