Справочник Пользователя для Andrew Wireless Innovations Group RPT-MMR8-19I

Скачать
Страница из 43
4 Installation
ID No: 159967
Page 21
Nut M8 DIN 934
figure 4-4 Pole mounting.
  Hang the mounting brackets of the remote unit into the threaded bolts of the U-
beam, and fasten them immediately using the washers and nuts.
Ensure that there is free access to the electrical connections as well as to the
cabinet. The approved bending radius of the connected cables must not be
exceeded.
4.1.4.  Mounting of Fan Protection
Since the fan protection is required for the outdoor usage of a stand alone remote
unit, the mounting of this optional equipment is also described in this manual.
  To install the protective cover of the fan protection kit, first unscrew the four
screws with the respective lock washers from the cover of the remote unit’s air
inlet, and instead, screw in the four spacing bolts M4.0x30 with the four lock
washers M4.0 DIN125 that are part of the fan protection kit.
  Place the protective cover into the right position by fitting its four bore holes over
the spacing bolts and fasten it using the original lock washers and screws of the
remote unit. (These lock washers and screws are also part of the fan protection
kit and can be used as spare parts in case of loss.)
Optical remote unit