4 Installation
ID No: 159967
Page 29
Ø
Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of
the fibre optic cable that will be inserted in the optical connectors on the donor
interface box.
the fibre optic cable that will be inserted in the optical connectors on the donor
interface box.
Ø
Blow out the laser receptacle with clean and dry compressed air to remove
any particulate matter.
any particulate matter.
Ø
Connect the fibre optic cables by inserting the cable end into the laser
receptacle and aligning the key (on the cable end) with the keyed slot.
receptacle and aligning the key (on the cable end) with the keyed slot.
Ø
Do not use any index matching gels or fluids of any kind in these connectors.
Gels are intended for laboratory use and attract dirt in the field.
Gels are intended for laboratory use and attract dirt in the field.
F
Note:
If the unit is mounted inside a pole (see separate description) the
following procedure has to be strictly observed:
following procedure has to be strictly observed:
G0946MC