2.4  Electrical Installation
Note:
Electrical installation must be carried out in accordance with the
safety regulations of the local authorities. Due to safety reasons
electrical installation must be performed by qualified personnel
only.
Connection of the cables to/from the BTS and connection of power supply:
The cable to the external antenna to/from the BTS and the SMA-connector must be
ordered separately if reqired.
If the cable is part of the delivery, adjust the cable to a suitable length and connect
the SMA-connector.
Cut the antenna cable to the required
length. Strip the jacket at the cut end to the
length of 14 mm, the copper braiding
carefully to 8 mm and the inner insulation to
10 mm.
Place the split taper socket over the cable.
Insert the inner conductor into the opening
at the rear of the SMA pin. Slot the pin and
cable into the opening at the rear of the
SMA connector. Carefully push the copper
braiding over the knurled end of the
connector. Take care that none of the wires
of the copper braiding contact the inner
conductor. Pull the split taper socket over
the cable up to the base of the SMA-
connector. Complete the connection by
crimping the split taper socket with crimping
pliers.
split taper
socket
base     knurled end       pin
crimed SMA
connector