5 Functional Description 
 
ID No: 161692 
PRELIMINARY 
Page 85
 
5.4.1.3 Battery 
Backup 
 
In case power fails, a battery backup system for controller and modem has been 
implemented. This provides enough power for the controller that is integrated into the 
downlink DCM and the modem to operate for a limited period of time (see chapter 
7.2.3 Specifications for Optional Equipment for battery backup time). Within this time, 
the Node C will initiate a call to the OMC and alert the operator that power has been 
lost. All other functions will cease to work in case of power failure. 
 
The battery packs are protected from deep discharge by use of a low voltage 
disconnect unit. When performing preventive maintenance, make sure that all circuits 
are voltage free by disconnecting the battery cable (C1) from its connector (C2). In 
case of a power cycle, it is sufficient to press the “Battery disconnect button” to 
interrupt the voltage supply. After mains is connected again, the battery will be 
charged and the battery backup function will be activated automatically. 
 
 
figure 5-17 Battery backup module, exemplary 
 
The battery charge module is plugged directly onto the distribution & alarm board of 
the Interface Unit through connector C3.  
 
The battery pack should be discharged at regular intervals of about three months to 
optimize its service life. This service discharge may be activated via software 
depending on the software version. The time required for the discharge varies 
depending e.g. on the charge status of the battery pack. A fully charged battery may 
require up to some hours to be completely discharged. Consider this when activating 
the discharge and also observe the following note.  
Note: 
Please be aware that the backup function is not available during 
discharge. Thus, a primary voltage failure in that time will result in 
a complete system shut-down.  
It is recommended to replace the battery pack of the battery backup option after two 
years of usage as a preventive measure. The nominal lifetime of the battery pack is 
approx. two years under normal environmental conditions. 
Battery pack 
C1; to C2 of  
charge module 
Battery charge module 
LED 
C2 connector 
C3 connector
Battery 
disconnect button