Справочник Пользователя для Mitsubishi Electric Corp 232C-1P

Скачать
Страница из 44
27
Installation
Reference page
Series Recording Connection
Connect VCRs to be used as shown below.(
 page 12 for the menu setting)
Remote Recording Connection
Connect the VCR with a remote switch as to the right.  (
 page 12 for the menu setting and page 37 for the rating of each
terminal)
*1 : This connection is necessary 
        in case of 
Series Recording 2.
*1
1st VCR
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
2nd VCR
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
Remote switch
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
Synchronous Recording Connection
Connect VCRs as shown below. (
 page 14 for the menu setting)
Note
The number of VCRs to be connected varies by the recording time mode selected.
Switcher
1st VCR
VIDEO IN
VIDEO IN
VIDEO IN
CLK OUT
REC IN
CLK OUT
REC IN
2nd VCR
3rd VCR
Camera 1
Camera 2
Camera 3
Connection for External Time Clock Adjustment
Connect VCRs as shown below. (
 page 28 for the menu setting and page 37 for the rating of each terminal)
2nd VCR
1st VCR
Switch
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
RST
IN
REC GND ALM
ALM
MODE
CLK
OUT
CALL
*1 : When connecting the MODE OUT terminal of the first VCR with the RST IN terminal of the second VCR,
the on-screen clock of the second VCR can be adjusted to that of the first VCR.
*1