Справочник Пользователя для Chengdu Diyue Technology Co. Ltd. SZUO6A

Скачать
Страница из 31
SZU06A2 Product Manual
SZU06A2 PM(Rev 2.0)
11
5.2
Recommended operating conditions
Parameter
Min value
Typical value Max value Unit
Environment
Supply voltage
2.1
3.3
3.9
V
RF input power
-
-
10
dbm
RF frequency
2405
2480
MHz
Operating temperature
-40
25
85
-
Relative humidity
-
-
95
%
Table 5-3 Recommended Operating Conditions
6
DC Electrical Characteristics
V
3.3V,T
25
2400MHz 2483.5MHz.
DD
OP
C
f
℃,
Parameter
Test condition
Symbol
Value
Min.
Type
Max.
Supply Voltage
V
D D
2.1V
3.3V
3.9V
Supply Current
I
VDD
-
-
1000mA
Reset
I
reset
2.1mA
3mA
Hard reset
reset
t
1ms
FLASH
FLSH erase
C
erase
10000
-
-
Flash data retention
t
r e te n tio n
10years
-
-
Page erase
t
erase
20ms
40ms
I
r e a d
-
-
3mA
Write operation
I
w rite
-
-
3mA
RX Current
Receive enable
I
R X
-
14mA
14.2mA
TX Current
TX power = 0dBm
I
TX
-
15mA
16.7mA
TX power = 3dBm
-
20.2mA
21mA
TX power = 8dBm
29mA
31.2mA
32mA
Sleep Current
Enter EM2 mode
I
sleep
2.3μA
2.7μA
3.2μA
Enter EM3 mode
-
1.7μA
-
Enter EM4 mode
-
0.5μA
-
Wake up time
From EM1 to wake
1
t
em
w u
-
3μs
-