HXC Client Module User Guide
Version 1.09
© 2017 All rights reserved. Iotek Systems, LLC
Page 47 of 59
AT+RX=0 
// Turn off the reception.
 
>>>
OK 
The received data will be printed using UART.
>>>
rxDone 
>>>
rxdata:<Hex Bytes>
Users  can  receive  AT_BUSY_ERROR  if  the  command  is  used  during  a  LoRa  packet
transmission (Join, Packet send or Continuous Tx).
AT+RX=1 
>>>
AT_BUSY_ERROR 
Users can receive AT_INVALID_MODE if the +MODE is not LORA.
AT+RX=1 
>>>
AT_INVALID_MODE 
8.7.5.5  AT+TXCW: Continuous Transmit
This  command  allows  the  user  to  set  the  radio  to  output  the  fundamental  frequency
(unmodulated).  It  is  mainly  used  for  ETSI  and  FCC  certification.  It  will  use  AT+RFCFG 
command’s  <Freq>,<SF>,<BW>,<PWR>  parameters.  This  command  doesn’t  depend
on AT+MODE configuration.
Format:
AT+TXCW=<timeout in seconds>
AT+TXCW? 
>>>
Turn ON Continuous Tx 
>>>
OK 
AT+TXCW=60 
>>>
OK 
Users  can  receive  AT_BUSY_ERROR  if  the  command  is  used  during  a  LoRa  packet
transmission (Join, Packet sending or Continuous Tx).
AT+TXCW=10 
>>>
AT_BUSY_ERROR 
8.7.6  Diagnostic Commands
This  section  provides  a  set  of  commands  to  provide  diagnostic  information  on  the  RF
signal quality and battery level.
8.7.6.1  AT+BAT: Set Battery Level
This  command  allows  users  to  set  the  battery  level  of  the  client.  If  the  network  server
requests for device status (DevStatusReq) this battery level, along with the last received
packet’s SNR, will be incorporated in the ‘DevStatusAns’.
Battery
Description
0
The end-device is connected