10. Basic Troubleshooting 
 
Some things to check if there is trouble communicating. 
 
 Check that: 
 
•  All connections are dry and free of dirt 
•  All connections are sound 
•  The battery is connected and has some charge 
•  The antenna is connected 
•  Change frequencies and/or antennas 
•  Go back to the last known point with good communications 
 
 
11. Operation Specifications 
 
 
Temperature Range: -30 to +60 degrees C (-22 to +140 degrees F) 
Derate upper temperature limit by 1 degree C (1.8 degree F) for each 1000 feet above sea level. 
Cooling is convection from case – remove from or open backpack as needed. 
 
Relative Humidity: up to 95%, non-condensing 
 
Maximum battery life (TX:RX ratio 1:9): 30 hours 
 
RF Power Output: 25 watts PEP (high) and 5 watts PEP (low) 
 
Duty Cycle: 50% normal speech over full temperature range 
 