Converted Frequency Formula
Use the following formula to calculate the converted frequency:
TX:
ƒ
RF OUT
(GHz) =
ƒ
IF IN
(GHz) + 24.6
RX:
ƒ
IF OUT
(GHz) = 24.6 -
ƒ
RF IN
(GHz)
Note: Vent holes are covered with a Goretex
TM
patch.
Note: The transceiver mounts to a vertical pole of 2.5” to 4.5” outside diame-
ter. It has a range of motion of 90
ter. It has a range of motion of 90
°
over and -60° under horizon. The bases of
the antenna mount can rotate
±
180
°.
Technical Assistance Contact Information
In case additional technical assistance is required, or the transceiver unit is
damaged upon receipt, contact Nortel Networks.
damaged upon receipt, contact Nortel Networks.
Nortel Networks Broadband Wireless Access (BWA) provides 24-hour customer
service and technical support to ensure your service operation is trouble-free.
If you have questions or need technical support, contact Nortel Networks
Broadband Wireless Access at the following telephone numbers:
service and technical support to ensure your service operation is trouble-free.
If you have questions or need technical support, contact Nortel Networks
Broadband Wireless Access at the following telephone numbers:
• In the USA and Canada, call 972-BWA-ETAS/972-292-3827