Technical Support 
Mobileye 5 – Technical Installation Guide_Rev 0.1 
Nov, 2011 
Page 20 of  38 
 
Mobileye Proprietary and Confidential
 
support@mobileye.com 
 
4  System Calibration Procedure 
 
CAUTION: When Performing System Calibration DO NOT: 
-  Disconnect the EyeWatch connection 
-  Move the laptop carelessly 
-  Turn off the vehicle or in any other way turn off power to the Mobileye 5 system 
 
4.1  Removing the Mobileye 5 Back Covers 
 
In order to calibrate the Mobileye 5, the camera angle must be set prior to the 
calibration process. To access the camera adjustment screw there is a need to 
remove the Mobileye 5 Main Unit Back Covers.  
 
To remove the Main Unit Back Covers follow the below instructions: 
1.  Insert a small screw driver at the slightly larger circles at the right and Left 
ends of the lower part of the Main Unit Back Cover and press the bracket to 
release.