Справочник Пользователя для ICOM 288800

Скачать
Страница из 134
96
11
MENU SCREEN OPERATION
■ Scan set mode items
D
Priority watch
Activates priority watch or priority watch with alert 
(Bell)
.
• OFF : The priority watch is turned OFF. 
(default)
• ON
: The transceiver checks the memory channel fre-
quency every 5 sec.
• BELL : The transceiver checks the memory channel fre-
quency every 5 sec. You can be alerted with
beeps and blinking “S”.
D
Scan pause timer
Selects the scan pause time. When receiving signals, the
scan pauses according to the scan pause time.
• 2–20 SEC : Scan pauses for 2–20 sec. on a received
signal  in 2 sec. steps. 
(default: 10 sec.)
• HOLD
: Scan pauses on a received signal until it dis-
appears. Rotate [DIAL] to resume manually.
D
Scan resume timer
Selects the scan resume time of a paused frequency after the
received signal disappears.
• 0
: Scan resumes when a received signal disap-
pears.
• 1–5 SEC : Scan pause 1–5 sec. after a received signal
disappears. 
(default: 2 sec.)
• HOLD
: Scan pauses on the received signal even if it
disappears. Rotate [DIAL]
to resume manu-
ally.
Scan resume timer must be set shorter than scan pause
timer 
(previous item)
, otherwise this timer does not activate.
2SEC
2SEC
4SEC
4SEC
3SEC
3SEC
1SEC
1SEC
5SEC
5SEC
RESUME TIMER
r
3SEC
3SEC
5SEC
5SEC
4SEC
4SEC
2SEC
2SEC
HOLD
HOLD
RESUME TIMER
r
10SEC
10SEC
6SEC
6SEC
8SEC
8SEC
4SEC
4SEC
12SEC
12SEC
PAUSE TIMER
r
20SEC
20SEC
16SEC
16SEC
18SEC
18SEC
14SEC
14SEC
HOLD
HOLD
PAUSE TIMER
r
OFF
OFF
ON
ON
BELL
BELL
PRIO WATCH
PRIO WATCH
r
OFF
OFF
ON
ON
BELL
BELL
PRIO WATCH
r