16
3
BASIC OPERATION
 User set mode
User set mode is accessed at power ON and allows you to 
set seldom-changed settings. You can “customize” the trans-
ceiver operation to suit your preferences and operating style.
Entering the user set mode:
q
  While pushing and holding [P1] and [P2], rotate [VOL] to 
turn the power ON.
  • Turn power OFF in advance.
  • “SET MODE” appears for 1 sec at power ON.
w
 Push and hold [P0] to enter user set mode. 
e
  Push [P0] several times to select the appropriate item.
   Then push [Side2] or [Side3] to set the desired level/con-
dition.
  •  Available set mode functions are 
BacklightLCD contrast
BeepBeep LevelRinger LevelSQL LevelAF Min Level
Mic GainVOX GainVOX DelayBattery VoltageSignal 
Moni
 and Lone Worker.
r
  Push and hold [P0] again to exit set mode.
User set mode is also available using a programmable key. 
Please refer to p. 10 [User Set Mode] section for instructions 
regarding using the key assigned for user set mode.
 
 NOTE: [Side2] or [Side3] and [P0] activate while in the 
user set mode regardless of the assigned key functions.
 Emergency transmission
When [Emergency] is pushed for the specified time period, 
an emergency signal is automatically transmitted. (p. 9)
When [Emergency] is pushed for the specified time period, 
the DTMF emergency signal is transmitted once or repeat-
edly on the emergency channel. However, when no emer-
gency channel is specified, the signal is transmitted on the 
previously selected channel.
If you want to cancel the emergency call, push and hold the 
key again before transmitting the call.
 Man Down Emergency Call
This function requires the optional UT-124R 
man
 
down
 
unit
 
and can be performed in conventional mode.
The man down emergency call function transmits an emer-
gency call automatically when the transceiver has been left 
in a horizontal position.
After the emergency call, the transceiver performs transmis-
sion and reception alternately with receiving a signal and 
emitting audio.
When the emergency reset signal is received, the function is
cancelled.
 
 IMPORTANT: Set an emergency channel individually, to 
provide certain emergency call operation is recommended.