PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
No sound from speaker. • Squelch level is too high.
• Volume level is too low.
• Speaker has been exposed to water.
p. 7
p. 7
p. 9
• Set
[SQL] to the threshold point.
• Set
[VOL] to a suitable level.
• Drain water from the speaker.
The transceiver does 
not turn ON.
• Bad connection to the power supply.
p. 44
• Check the connection to the transceiver.
Transmitting is impos-
sible, or high power can 
not be selected.
• Some channels are for low power or re-
ceive only.
• The output power is set to low.
pp. 5, 6, 
52
p. 7
• Change channels.
• Push
[HI/LO] on the microphone to select 
high power.
Scan does not start.
• TAG channel is not programmed.
• Set a desired channels as TAG channels.
p. 11
No beeps.
• Beep tones are turned OFF.
• Turn the beep tone ON in the Set mode.
p. 42
Distress call cannot be 
transmitted.
• MMSI  (DSC  self  ID)  code  is  not  pro-
grammed.
• Program the MMSI (DSC self ID) code.
p. 13
52