Справочник Пользователя для ICOM 318200

Скачать
Страница из 124
54
5
FUNCTIONS FOR RECEIVE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
N
The Band Scope function allows you to visually check 
the location and strength of signals around a specified 
frequency.
The IC-7410’s Band Scope function can be used in 
any operating mode and any frequency band.
INDICATOR
DESCRIPTION
3WEEP
While the band scope is sweeping, “
” is displayed; while stopped, “
” is displayed.
2ECEIVED
"AND
DISPLAY
Displays the signal location and strength in relation to the center (displayed) frequency. Signal strength is 
relative to the S-meter level, S1 to S9, with each vertical dot in the band scope indicator equal to one seg-
ment of the S-meter. Signal activity is measured ±30 steps from the center frequency, with each step equal 
to the selected sweep step.
&REQUENCY 
DISPLAY
After a sweep, displays the relative position of the reference frequency. When the reference frequency is 
outside of the sweep range, “ ” or “ ” blinks. After changing the frequency, hold down [F-3] for 1 second to 
automatically return to the center frequency.
3WEEP
DISPLAY
Displays the selected sweep step. 0.5, 1, 2, 5, 10, 20 and 25 kHz are selectable. Each dot of the band scope 
display is approximately equal to the selected sweep step.
The band scope measures receive signal location 
and strength over a specified range on either side of 
a selected frequency, in either the VFO or memory 
modes.
q Rotate [DIAL] to select a frequency.
w  Push [MENU] to display the “M1” screen (Menu 1), 
then push [SCP](F-5) to display the “SCP” screen 
(Band Scope).
s
lected sweeping step.
s
e  Push [F-5] one or more times to select the desired 
sweep step.
0.5, 1, 2, 5, 10, 20 and 25 kHz are selectable.
r  Push [F-1] to start sweeping, then automatically 
stop after sweeping.
s
ing. In this case, push [F-1] again to stop the sweep-
ing.
s
” is displayed and received sig-
nals cannot be heard.
s
to reduce the signal input level, and turn ON the Attenu-
ator to improve the readability of the band scope.
t  Rotate [DIAL] to find a signal that you wish to com-
municate with. If you find the signal, communicate 
in the normal way.
s
before rotating [DIAL], hold down [F-3] for 1 second.
s
range, “ ” or “ ” blinks.
y  If you want to update the band conditions while re-
ceiving, repeat steps 
e and r.
SCP
0 . 5 k
S T E P
Sweep step display
Sweep icon
Band scope display
Frequency display mark
Blinks when the reference frequency 
is outside of the sweep range.
Sweep start/stop
Sweep step selection
Sweep icon
SCP
0 . 5 k
S T E P
SCP
0 . 5 k
S T E P
./4%
If you select a large sweep step, a wide frequen-
cy range can be displayed on the band scope, but 
some signals may be skipped and not displayed.