2.
Product Features
●
IP66
grade waterproof / dustproof design
●
Robust
WiFi security
●
Built-in UPS (automatic conversion during
blackout)
●
Ultra
low standby power
●
OLED
screen, strong in winter
●
Tapaculo365
(web storage, reports, alarm)
●
Easy installation (supports both magnet and
screws)
●
Highly
durable F-RAM
●
External
micro SD memory
●
Door
Open sensing (EX-model)
●
RELAY
ON/OFF control (220V 1A, EX model)
●
Links
to user server (HTTP)
2.1. Power
Actions
Details
Turn
On Power
●
Once
‘POWER ON’ is pressed, the product shows the model name, firmware
version,
power connection type, UPS, basic measurement frequency, basic
transfer
frequency, and the name of the connecting WiFi channel.
●
When
WiFi connection fails:
CONNECT
TIMEOUT 25S
!! NO INTERNET !!
Shows
WiFi connection failure, and tries
to
reconnect to the network
NO
WIFI CONNECTION!
PRESS
‘W’ FOR SETUP
If
the device continues to fail to connect
to
WiFi, press ‘W’ and open the configu-
ration
settings.
Shows
SOFT AP and ACCESS address for
connection
Setup of the product.
(Refer
to 4.2. WiFi Settings)
⇩
SOFTAP:
_RN400-E2E8
ACCESS:
192.168.1.1
Turn
Off Power
●
When
the device is on ‘WAKEUP’ mode, press ‘POWER OFF ‘
[JK1]
,
which
will
show ‘PRESS ‘P’ ONE MORE TO POWER OFF’. Press ’P’ once more
then
the
device shows ‘POWER OFF! GOOD BYE’ and turns off.
Power
Supply
●
C
Type 1.5V X 2EA OR 3.6V X 1EA
●
Batteries
should be inserted when connecting to DC power supply for contact
control.
●
BUILT-IN
UPS: During a DC power blackout, converts automatically to
battery
mode(When using DC power supply, batteries are not used.)
Battery
Lifespan
●
2
years(when set at 10-min.sensing interval frequency)
Battery
Saver
Mode
●
The
device operates on Battery Saver Mode as the default other than during
data
sensing and transfer. Press ‘WAKE UP’ to activate the device to change