32 
UPC-A 
Read: Format 
Leading zero  Data digits (11 digits)  Check digit
Check digit verification: The check digit is optional. 
Check digit trans.: By setting Enable, check digit will be transmitted. 
Code  ID  setting:  Code  ID  is  a  one-or-two-character  string  used  to  represent  the  symbol  upon  a 
succeeding reading.    If you want application to transmit Code ID, you must set Code ID transmission to 
be enabled.    Refer to the chapter of String transmission. 
Insertion group selection: Refer to Global insertion group selection of the chapter of Hand-held scan & 
some global settings. 
Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters. 
Format 
Leading zero 
Data digits (11 digits) 
Check digit
Supplement digits 2 or 5 
Truncation/Expansion: 
Truncate  leading  zeros-  The  leading  “0”  digits  of  UPC-A  data  characters  can  be  truncated  when  the 
feature is enabled. 
Expand to EAN-13- It extends to 13-digits with a “0” leading digit when the feature is enabled. 
 
    SETUP 
Option bar code 
Option 
Alpha. entry 
Read 
 
Disable 
Enable 
00 
01* 
Check digit verification 
 
Disable 
Enable 
00 
01* 
Check digit trans. 
 
Disable 
Enable 
00 
01* 
Code ID setting 
 
00-FF
16
   
(ASCII) 
00-FF
16
 
<A>* 
Insert group selection 
 
00-66 
 
00-66 
00* 
Supplement digits 
 
None 
2 digits 
5 digits 
2 or 5 digits 
00* 
01 
02 
03 
Truncation/Expansion 
 
None 
Truncate leading zeros 
Expand to EAN-13 
00* 
01 
02 
Reserved 
 
 
 