Справочник Пользователя для Shenzhen Unique Electronic Int'l Limited MS3398

Скачать
Страница из 71
 
43 
Code 93 
Read: 
Format 
Data digits (variable)  2 check digits (optional)
Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data 
digits. 
Check digit transmission: By setting Enable, check digit will be transmitted. 
Max./Min. code length: Refer to Max./Min. code length of Code 39. 
Code ID setting: Refer to Code ID setting of UPC-A. 
Insertion group selection: Refer to Insertion group selection of UPC-A. 
 
    SETUP 
Option bar code 
Option 
Alpha. entry 
Read 
 
Disable 
Enable 
00 
01* 
Check digit verification 
 
Disable 
Enable 
00 
01* 
Check digit transmission 
 
Disable 
Enable 
00* 
01 
Max. code length 
 
00-99 
 
00-99 
00* 
Min. code length 
 
00-99 
 
00-99 
01* 
Code ID setting 
 
00-FF
16
 
(ASCII) 
00-FF
16
 
<L>* 
Insert group selection 
 
00-66 
 
00-66 
00* 
Reserved 
 
 
 
    END