Справочник Пользователя для Ulterius Technologies LLC FDN40
CHAPTER 5: VLAN
Configuration User Manual
125
© Ulterius Technologies, LLC 2016. Confidential & Proprietary.
arrives. Port-based classification requires the association of a specific VLAN
ID, the port VLAN identifier (PVID) with each port.
ID, the port VLAN identifier (PVID) with each port.
A port can be a member of only one port-based VLAN.
If PVID value has not been explicitly configured for a port, then PVID assumes a
default value of 1.
default value of 1.
1. Execute the following commands to configure the PVID that is assigned
to untagged/priority-tagged frames.
Enter the Global Configuration Mode.
UltOs# configure terminal
Enter the Interface Configuration Mode for port gigabitethernet 0/1.
UltOs(config)# interface lan 0/1
Configure the PVID that is to be assigned to untagged/priority-tagged
frames.
frames.
UltOs(config-if)# switchport pvid
2. View the configuration details by executing the following show command.
UltOs# show VLAN port config port lan 0/1
VLAN Port configuration table
-------------------------------
Port lan0/1
Port VLAN ID : 4
Port Acceptable Frame Type : Admit All
Port Ingress Filtering : Disabled
Port Mode : Hybrid
Port Gvrp Status : Enabled
Port Gmrp Status : Enabled
Port Gvrp Failed Registrations : 0
Gvrp last pdu origin :
00:00:00:00:00:00
00:00:00:00:00:00
Port Restricted VLAN Registration : Disabled
Port Restricted Group Registration : Disabled
Mac Based Support : Disabled
Port-and-Protocol Based Support : Enabled
Default Priority : 0
--------------------------------------------------
5.5.4.2
WEB Configuration
VLAN Frame Classification can be configured through WEB interface using
VLAN Port Settings screen (Navigation - Layer2 Management > VLAN >
PortSettings)
VLAN Port Settings screen (Navigation - Layer2 Management > VLAN >
PortSettings)