CHAPTER 5: VLAN 
Configuration User Manual 
125 
© Ulterius Technologies, LLC 2016. Confidential & Proprietary. 
arrives. Port-based classification requires the association of a specific VLAN 
ID, the port VLAN identifier (PVID) with each port. 
 
A port can be a member of only one port-based VLAN. 
 
If  PVID  value  has  not  been  explicitly  configured  for  a  port,  then  PVID  assumes  a 
default value of 1. 
1.  Execute the following commands to configure the PVID that is assigned 
to untagged/priority-tagged frames. 
 
Enter the Global Configuration Mode. 
UltOs# configure terminal 
 
Enter the Interface Configuration Mode for port gigabitethernet 0/1. 
UltOs(config)# interface lan 0/1 
 
Configure the PVID that is to be assigned to untagged/priority-tagged 
frames. 
UltOs(config-if)# switchport pvid  
2.  View the configuration details by executing the following show command. 
UltOs# show VLAN port config port lan 0/1 
VLAN Port configuration table 
------------------------------- 
Port lan0/1 
 
 Port VLAN ID                        : 4 
 Port Acceptable Frame Type          : Admit All 
 Port Ingress Filtering              : Disabled 
 Port Mode                           : Hybrid 
 Port Gvrp Status                    : Enabled 
 Port Gmrp Status                    : Enabled 
 Port Gvrp Failed Registrations      : 0 
 Gvrp  last  pdu  origin                                : 
00:00:00:00:00:00 
 Port Restricted VLAN Registration   : Disabled 
 Port Restricted Group Registration  : Disabled 
 Mac Based Support                   : Disabled 
 Port-and-Protocol Based Support     : Enabled 
 Default Priority                    : 0 
 -------------------------------------------------- 
5.5.4.2 
WEB Configuration 
VLAN Frame Classification can be configured through WEB interface using 
VLAN Port Settings screen (Navigation - Layer2 Management > VLAN > 
PortSettings)