Справочник Пользователя для Ulterius Technologies LLC FDN40
FDN40
`FDN40ConfigUM/20160505
271
© Ulterius Technologies, LLC 2016. Confidential & Proprietary.
15.3 Configuration Guidelines
The following sections describe the configuration of OSPF running as a part
of ULTERIUS FDN40 product.
of ULTERIUS FDN40 product.
This is a prerequisite for configuring the OSPF.
15.3.1 Configuration in FDN40-1
Prerequisite: Configuration of VLAN Interfaces (vlan11 and vlan10)
UltOs# configure terminal
UltOs(config)# vlan 11
UltOs(config-vlan)# ports wan 0/1 untagged wan 0/1
UltOs(config-vlan)# exit
UltOs(config)# interface vlan 11
UltOs(config-if)# shut
UltOs(config-if)# ip address 10.4.0.1 255.255.0.0
UltOs(config-if)# no shutdown
UltOs(config-if)# exit
UltOs(config)# vlan 10
UltOs(config-vlan)# ports wan 0/2 untagged wan 0/2
UltOs(config-vlan)# exit
UltOs(config)# interface vlan 10
UltOs(config-if)# shutdown
UltOs(config-if)# ip address 10.10.2.1 255.255.255.0
UltOs(config-if)# no shutdown
UltOs(config-if)# exit
UltOs(config)# interface wan0/2
UltOs(config-if)# switchport pvid 10
UltOs(config-if)# no shutdown
UltOs(config-if)# exit
15.3.2 Configuration in FDN40-2
Prerequisite: Configuration of VLAN Interfaces
UltOs# configure terminal
UltOs(config)# vlan 11
UltOs(config-vlan)# ports wan 0/1 untagged wan 0/1
UltOs(config-vlan)# exit
UltOs(config)# interface vlan 11