Table 3 – Possible sensor types on each CLOG500.
Note: In order to use input 3 “SIG(3)” in variant EXC5_00XY as Digital Input or Digital
Impulses is necessary to place the Jumper S2 in the Open Position.
9.1.1 Sensors connect through radio device
For sensors connect via a radio device (RTU), the input number to put in the installation
message is the “Radio ID:” field presented in the technical label of the radio device. This
number can have any value from 10 to 65530.
10 Tips and Tricks
Here are some useful tips and tricks for CLOG500 installer:
For level sensors use channel 1 to 2 because the CLOG500 sends instant data to
these channels. Instant data is very useful for level sensors.
Always configure cabled sensor on channel 1 and wireless sensor on channel 2
(wireless sensors are available only on some CLOG500 models).
When passing the magnet to activate equipment, rub it 3 or 4 times.
The PIN code of the SIMCard should be deactivated or changed to the PIN code
provided by ISA.