Figure 8-14 Saved Custom Personality 
 
 
8.3  Download Custom Personality 
With the new custom personality complete, the next step is to download the Web Utility generated 
personality configuration file to the PC. 
 
  Simply click on the “Download” link for the new personality in the “My Personality List” and 
save the GATT_xxx.bin file to the PC and note the location where it is saved.    The name of the 
personality file can changed as desired. 
8.4  Load Personality to Flash 
Now that the custom Odyssey personality configuration is accessible on the PC, the user needs to 
load it to one of the 15 personality “slots” available on the Odyssey kit.    This is achieved via the 
USB  cable  connected  to  the  Odyssey  and  loading  the  binary  configuration  file  using  a  serial 
communication protocol.    Be sure to have the USB virtual serial COM port drivers installed before 
connecting the Odyssey kit.    See section 2.2.6 for details. 
 
  Power  up  the  Odyssey  kit  with  the  USB  cable  connected  to  the  PC.    Upon  successful 
connection, a virtual serial COM port will be opened between the PC and the device.    (Wait for 
the Windows device connection tone.)    Use the Device Manager to determine the COM port 
number assigned to the Odyssey kit. 
 
  Open  a  Tera  Term  session  using  the  above  COM  port  and  establish  a  connection  using  the 
following settings: