On the main PAS screen, press F4 to cycle through side panel modes. The three available modes are: 
a)  Full tag list (no video) 
b)  Mini tag list with one IP camera view (depicted above) 
c)  No tag list, two IP camera views. 
Click on a camera window to cycle through the available cameras. 
In addition to IP cameras, one analog camera is supported. But only one type or the other may be used, not both. If 
there are no IP cameras detected, then pressing F5 will display the analog camera feed. The analog camera is only shown 
full screen and can’t be displayed in the side panel. 
 
Vehicle Occupants 
To suppress the tags worn by the driver and any other occupants of the vehicle, select the tag in the tag list (highlighted 
with a green border) and press F3. Repeat for any other occupants. 
Press F3 with no tags selected to restore all occupant tags to the list.  If a tag leaves its own vehicle’s coverage area, it 
will automatically lose occupant status. 
 
Notifications 
Notifications appear on the Controller’s main PAS screen (see 7 in Figure 24).  Some of the notifications include: 
Time of Day = the current time is shown when there are no tags detected 
Tags Detected = total number of tags detected 
Changes Saved = setup menu changes saved (using F1) 
Data Connection Lost = Communication between the Controller and the Aggregator has been lost.  Check connections. 
Connection restored = Communication between the Controller and the Aggregator has been restored.   
Faulty Sensors = Lists the sensor(s) that require service.  LF = Left Front; RF = Right Front; LC = Left Center; RC = Right 
Center; LR = Left Rear; RR = Right Rear 
Overloaded Sensors = Lists the sensor(s) that require service.  (see above) 
Inside: [Geofence name] = Lists the name of the geofence the vehicle has entered. 
Exited: [Geofence name] = Lists the name of the geofence the vehicle has exited. 
CAUTION: Many tags = There are a high enough number of tags detected that the accuracy and responsiveness of the 
system could be adversely affected. 
 
Other Features 
Event Log  
Automated event log recording. 
 
Maintenance 
Never  open  any  PAS  equipment.    For  safety  reasons,  the  equipment  should  be  opened  only  by  qualified  service 
personnel.