Справочник Пользователя для InVue ED0991

Скачать
Страница из 18
 
 
3.4.  Transmitter AC Characteristics 
 
Tamb = 25 ˚C, all supplies centered on typical values 
Table 9 Transmitter AC Characteristics 
Parameter 
Min 
Typ 
Max 
Units 
Condition/Notes 
Frequency range 
3244 
3993.6  6999 
MHz 
Must be set to 3993.6MHz 
to comply with FCC/ETSI 
certification. 
Channel Bandwidth 
 
500 
 
MHz 
See DW1000 Datasheet [2] 
Power Level Range 
 
24 
37 
dB 
Must be set to 24dB to 
comply with FCC/ETSI 
certification. 
Coarse Power Level Step 
 
 
dB 
 
Fine Power Level Step 
 
0.5 
 
dB 
 
Output power variation with 
temperature 
 
0.05 
 
dB/°C 
 
Output power variation with 
voltage 
 
2.73 
 
dB/V 
Channel 2 
 
3.5.  Temperature and Voltage Monitor 
 
Tamb = 25 ˚C, all supplies centered on typical values 
Table 10 Temperature and Voltage Monitor 
Parameter 
Min 
Typ 
Max 
Units 
Condition/Notes 
Voltage Monitor Range 
2.4 
 
3.75 
 
Voltage Monitor Precision 
 
20 
 
mV 
 
Voltage Monitor Accuracy 
 
140 
 
mV 
 
Temperature Monitor Range 
-40 
 
+100 
°C 
 
Temperature Monitor Precision 
 
0.9 
 
°C 
 
 
3.6.  Antenna 
 
The antenna used in the module is the Partron dielectric chip antenna, part number ACS5200HFAUWB, 
see [4] for full detail