The  operator  must  prepare  external  against  lightning  protector  to  protect  the  GPS, 
external antenna and RJ-45 port. 
Grounding Notes: 
 
The ground wire adopts yellow-green wire that is no smaller than 16 mm². 
 
Grounding principle: as near as possible. 
 
The base station connects to the reliable outdoor grounding point (earth) through 
one ground screw. 
 
The  connection  of  the  grounding  points  and  the  ground  bar  need  to  be  tight  and 
reliable.  Rustproofing  the  terminals  is  required.  This  can  be  done  with  rust 
preventing paint, anti-oxidation coatings, grease, and so on. 
 
Weatherproof Protection 
2.6
The Nova-436  adopts  cold  shrink  tube for  weatherproof  protection.  Before  installing  the 
cold  shrink  tube,  clean  up  the  interface  first.  The  weatherproof  protection  steps  are  as 
follows: 
1.  Insert cable into cold shrink tube. 
2.  Tighten the connector. 
3.  Push the cold shrink tube to the top joint and pull out the strip. 
4.  Check whether the cold shrink tube tight connect with the connection. 
 
 
Regulatory Compliance 
2.7
FCC Compliance 
This device complies with part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that 
may cause undesired operation.