Справочник Пользователя для Tele Supply AS JTM-30C
Document ID
Rev.
Rev Date
5. OPERATOR MANUAL JTM-30
PN2
June 7
th
2016
5. JTM-30C NDB Operation User Manual
Copyright 2014 - TELE SUPPLY AS
Page 2(14)
5.
OPERATION AND MONITORING OF THE NDB TRANSMITTER TYPE JTM-30C
Operation and monitoring of the NDB Transmitter is possible with external mounted Remote Controls and/or
operation for dedicated PC directly connected to the equipment, or from PC via Internet
operation for dedicated PC directly connected to the equipment, or from PC via Internet
5.1 Operation from Remote Control Units Type JTM-30R
Switching the equipment ON (Activate), OFF (Deactivate) and Remote.
Remote Control Units may be daisy chained.
Remote Control Units may be daisy chained.
The Remote Control is provided with following indicators and switches:
• LED indicating DC Voltage input to the Transmitter «DC ON»
• LED indicating which transmitter in operation «TXA» or «TXB»
• LED Indicating sufficient «RF Output» from the Transmitter «CARR»
• LED indicating Morse signal «MOD»
• LED indicating Alarm «ALARM»
• Switch for switching the Transmitter ON/OFF/Remote
• LED indicating which transmitter in operation «TXA» or «TXB»
• LED Indicating sufficient «RF Output» from the Transmitter «CARR»
• LED indicating Morse signal «MOD»
• LED indicating Alarm «ALARM»
• Switch for switching the Transmitter ON/OFF/Remote
«Activate/Deactivate/Remote»
• Switch for switching the local Loud Speaker ON or OFF
Front Panel view
5.1.1
LED indication DC Voltage input to the Transmitter «DC ON».
If this LED is lit it indicates that there is DC supply voltage (nominal 24V DC) into
the NDB Transmitter, and that the Fuse F1 inside the Transmitter cabinet is ON