stand-alone media converter
Specifications
Standards
ITU-T, ANSI, AT&T, ETSI
Switches
SW1: 1, 2, 3: Line Build out for short haul/DB in
Long Haul (see table)
Short Haul mode:
SW1: Pos 4 not used
SW2 - 1: Transmit all ones into copper on loss
of fiber link (UP = Disabled)
SW2 - 2: Transmit all ones (AIS) into fiber on
loss of copper link (UP = Disabled)
SW2 - 3: Long Haul/Short Haul
(UP = Short Haul)
SW2 - 4: T1/E1 selection (Up = T1)
Long Haul (see table)
Short Haul mode:
SW1: Pos 4 not used
SW2 - 1: Transmit all ones into copper on loss
of fiber link (UP = Disabled)
SW2 - 2: Transmit all ones (AIS) into fiber on
loss of copper link (UP = Disabled)
SW2 - 3: Long Haul/Short Haul
(UP = Short Haul)
SW2 - 4: T1/E1 selection (Up = T1)
3-position Jumper
Hardware: mode is determined by 4-position
switch settings
Software: mode is determined by most re-
cently saved on-board microprocessor settings.
switch settings
Software: mode is determined by most re-
cently saved on-board microprocessor settings.
Status LEDs
PWR (Power): Steady green LED indicates
connection to external AC power
SDC (Signal Detect/Copper): On indicates
twisted pair link is up
SDF (Signal Detect/Fiber): On indicates fiber
link is up
connection to external AC power
SDC (Signal Detect/Copper): On indicates
twisted pair link is up
SDF (Signal Detect/Fiber): On indicates fiber
link is up
Dimensions
Width: 3.25" [82 mm]
Depth: 4.8" [122 mm]
Height: 1.0" [25 mm]
Depth: 4.8" [122 mm]
Height: 1.0" [25 mm]
Power
External AC/DC provided; 12V DC; 0.5A; unreg-
ulated; standard;
UL listed
ulated; standard;
UL listed
Environment
0 – 50°C, 5% – 95% humidity (non-condens-
ing), 0 – 10,000 ft.
ing), 0 – 10,000 ft.
Shipping Weight
2 lbs. [0.90 kg]
Safety Compliance
Wall Mount Power Supply:
CSA certified
CSA certified
Regulatory Compliance
CISPR/EN55022 Class A;
FCC Class A; CE Mark
FCC Class A; CE Mark
Warranty
Lifetime
see also:
T1/E1 Point System™ Slide-In-Module NID
T1/E1 Copper to Fiber
with Remote In-Band Management
Ordering Info
SSDTF1011-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 850 nm multimode (ST)
[2 k m/1.2 mi.] Link Budget: 13.5 dB
SSDTF1013-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 850 nm multimode (SC)
[2 km/1.2 mi.] Link Budget: 13.5 dB
SSDTF1027-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1300 nm multimode (ST)
[5 km/ 3.1 mi.] Link Budget: 13.5 dB
SSDTF1012-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
1310 nm single mode (ST)
[8 km/ 5 mi.] Link Budget: 7.0 dB
SSDTF1022-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1310 nm single mode (ST)
[15 km/ 9.3 mi.] Link Budget: 10.0 dB
SSDTF1014-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1310 nm single mode (SC)
[20 k m/12.4 mi.] Link Budget: 16.0 dB
SSDTF1015-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1310 nm single mode (SC)
[40 km/24.9 mi.] Link Budget: 30.0 dB
SSDTF1016-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1310 nm single mode (SC)
[60 km/37.3 mi.] Link Budget: 33.0 dB
SSDTF1017-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1550 nm single mode (SC)
[80 km/49.7 mi.] Link Budget: 29.0 dB
Single Fiber Products
Recommended use in pairs
Recommended use in pairs
SSDTF1029-120
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1310 nm TX / 1550 nm RX single fiber SM (SC)
[20 km/12.4 mi.] Link Budget: 19.0 dB
SSDTF1029-121
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1550 nm TX / 1310 nm RX single fiber SM (SC)
[20 km/12.4 mi.] Link Budget: 19.0 dB
SSDTF1029-122
Twisted Pair (RJ-48)
[1.5 km/0.9 mi.]
to 1310 nm TX / 1550 nm RX single fiber SM (SC)
[40 km/24.9 mi.] Link Budget: 25.0 dB
SSDTF1029-123
Twisted Pair (RJ-48)
[1.5k m/0.9 mi.]
to 1550 nm TX / 1310 nm RX single fiber SM (SC)
[40k m/24.9 mi.] Link Budget: 25.0 dB
Devices must be used in pairs. Typically installation will include a chassis
card (CSDTF, see pages 61-62) installed in the Point System™ locally and a
stand-alone device installed at the remote location.
card (CSDTF, see pages 61-62) installed in the Point System™ locally and a
stand-alone device installed at the remote location.
Optional Accessories
(sold separately)
(sold separately)
Wide Input (18 – 72VDC) Power Supplies:
SPS-1872-PS
Piggy Back Power Supply
SPS-1872-SA
Stand-Alone Power Supply
Mounting Options:
E-MCR-05
12-slot Media Converter Rack
RMS19-SA4-01
4-slot Media Converter Shelf
WMBD
DIN Rail Bracket 5.0" [127 mm]
WMBD-F
DIN Rail Bracket (flat) 3.3" [84 mm]
WMBL
Wall Mount Bracket 4.0" [102 mm]
WMBV
Vertical Wall Mount Bracket 5.0" [127 mm]