Selecting the remote controller functions
• Change the settings of the remote controller functions 
as required by taking the steps below.
How to change the remote controller functions
1
While operation is shut down, push the 
 button 
(43) and 
 button (48) together for at least 4 
seconds.
• The numeric displays and 
 display blink, 
and the fixed louvers display lights. 
2
Push the TEMP 
 and 
 buttons (49).
• Repeatedly push the buttons until the setting to be 
changed blinks on the display.
3
Push the TIME 
 and 
 buttons (40).
• Repeatedly push the buttons until the setting to be 
changed blinks on the display.
4
Push the 
 button (42). Then push the 
 button 
(43) to return to the original screen.
• When the 
 button (42) is pushed, the numeric 
displays and 
 display stop blinking and 
light up, and when the 
 button (43) is pushed 
again, they go off.
Items to be set
• 24-hour/12-hour display setting <code No.10>
– The 24-hour display or 12-hour (AM/PM) display 
can be selected for the clock which is displayed on 
the remote controller.
– This item’s selection is also reflected on the clock 
displayed on the clock setting screen and program 
input screen.
• Restriction on button operations <code No.12>
This item sets the range of the restriction placed on 
the button operations which can be applied while 
scheduled operations are being performed.
Setting: 0000 (factory setting)
Code No.12
O: Can be operated.
X: Cannot be operated. 
• Display/non-display of clock <code no.13>
This item selects and sets whether the day of the week 
and clock time are to be displayed.
Setting: 0000 (factory setting)
Code No.13
O: Display   X: No display
• Selection of operation when power is restored after a 
power outage <code No.14>
This item selects the operation to be performed when 
power is restored after a power outage occurred 
during a scheduled operation.
0000: No operations are performed when the power is 
restored, and the scheduled operation is resumed as 
soon as the program time is reached after the power 
has been restored. (When the power is restored, the 
scheduled operation is based on the operation of the 
indoor units.)
0001: If there was a programmed operation during the 
power outage, that operation is performed when the 
program is resumed. If there is no programmed 
operation or if the “Continue xx” setting is in place, the 
operation prior to the power outage is resumed.
Selecting the functions using the DIP 
switches of the remote controller
• The following functions can be selected using the DIP 
switches on the remote controller’s circuit board.
Setting procedure
• Open the back cover of the remote controller, and 
select the functions using the DIP switches located at 
the bottom left of the circuit board.
• After establishing the settings, turn the ground fault 
interrupter off and then back on.
Setting items
• Remote controller header/follower setting: Bit 1
When operating the air conditioner using two remote 
controllers, set one of the controls to be the follower.
* Set the remote controller used as the schedule timer 
to be the header. 
• Operation function setting: Bit 2
One of the following three operation functions can be 
selected and set.
1.Scheduled operation function
2.Timer operation function
3.No scheduled or timer operation function
Setting
Description
0000:
0001:
24-hour display (factory setting)
12-hour (AM/PM) display
Setting
[ON/OFF]
[MODE]
[TEMP.]
0000
O
O
O
0001
X
O
X
0002
X
X
X
0003
O
X
X
0004
O
X
O
Setting
Scheduled operation 
underway
Scheduled operation 
in standby
Air 
conditioner 
now 
operating
Air 
conditioner 
now shut 
down
Air 
conditioner 
now 
operating
Air 
conditioner 
now shut 
down
0000
O
O
O
O
0001
X
X
X
X
0002
O
O
X
X
0003
O
X
X
X
0004
O
O
O
X
0005
O
X
O
X
MB FRIGO Grupa d.o.o., Bani 81, 10010 Zagreb, www.toshiba.hr, e-mail: toshiba@mbfrigo.hr