Справочник Пользователя для Toshiba RBC-AMS41E

Скачать
Страница из 21
GRUPAd.o.o.
6
Correct operating procedures
The functions will differ depending on the model and 
system.
• Follow the steps below before using the remote 
control system for the very first time or when changing 
any of the settings.
• After the steps have been followed, operation will 
commence using the settings established simply by 
pushing the 
 button (32).
Preparations
Turn on the ground fault interrupter.
• When the power is turned on, a dividing line appears 
on the remote controller display.
* For about a minute after the power has been turned 
on, 
 on the LCD screen blinks, and there 
will be no response to the keys of the remote 
controller even when they are pushed.
Notes
• Do not turn off the ground fault interrupter during the 
operating season of the remote control system.
• After the remote control system has been shut down 
for a prolonged period, turn on the ground fault 
interrupter back on at least 12 hours before its 
operation is to be started.
Starting operation
1
Push the 
 button (32) to start operation.
• The ON lamp lights, and the operation details are 
displayed on the LCD screen.
2
Push the 
 button (34), and select the mode of 
operation.
• Each time this button is pushed, the operation 
mode display changes in the sequence shown 
below.
• Stop pushing the button when the symbol 
corresponding to the desired mode of operation 
lights.
3
Push the 
 button (32) to shut down 
operation.
• The ON lamp goes off, and the operation details 
are cleared from the LCD screen. (The frame lines 
remain displayed.)
• Before operation shuts down, the self-cleaning 
operation is commenced if the air conditioner was 
run in the Auto (during cooling), cooling or dry 
mode for 10 or more minutes.
* For details on the self-cleaning operation, refer to 
the “Self-cleaning operations” section.
Changing the air speed
1
Push the 
 button (33), and select the desired 
air speed.
• Each time the button is pushed, the air speed 
display changes in the sequence shown below.
• Stop pushing the button when the symbol 
corresponding to the desired air speed lights.
* If, during heating, the rooms do not heat up 
quickly at the low air speed setting, change the 
setting to high or medium.
* The auto air speed cannot be selected during fan 
operations.
Changing the temperature
1
Push the TEMP 
 and 
 buttons (49), and 
select the desired temperature setting.
• When the 
 button (49) is pushed, the 
temperature on the numeric display goes down; 
conversely, when the 
 button (49) is pushed, the 
temperature displayed goes up.
• The temperature cannot be set during fan 
operations.
Procedure for normal operation
Auto
Fan
Dry
Cooling
Heating
Auto air speed
Low air speed
Medium air speed
High air speed
MB FRIGO Grupa d.o.o., Bani 81, 10010 Zagreb, www.toshiba.hr, e-mail: toshiba@mbfrigo.hr