Справочник Пользователя для Trimble Outdoors SPSX51

Скачать
Страница из 188
9     Default Settings
106     SPSx51 Modular GPS Receivers User Guide
Default receiver settings
These settings are defined in the default application file. 
Resetting the receiver to factory defaults
To reset the receiver to its factory defaults, press 
E
     for 35 seconds.
Data Logging option
By default, the Data Logging option is turned off in SPS GPS receivers. If you choose to 
log data using a GPS receiver, you must enable the option and acquire suitable GPS 
postprocessing software, such as the Trimble Geomatics Office
 
software. For more 
information, please contact your Trimble dealer.
Postprocessed GPS data is typically used for control network measurement 
applications and precise monitoring. GPS measurement data is collected over a period 
of time at a static point or points and then postprocessed to accurately compute 
baseline information. 
Function
Factory default
SV Enable
All SVs enabled
General Controls:
Elevation mask
10°
PDOP mask
7
RTK positioning mode
Low Latency
Motion
Kinematic
Lemo Port:
Baud rate
38,400
Format
8-None-1
Flow control
None
Modem Port:
Baud rate
38,400
Format
8-None-1
Flow control
None
Input Setup:
Station
Any
NMEA/ASCII (all supported messages)
All ports Off
Streamed output
All types Off
Offset = 00
RT17/Binary
All ports Off
Reference position:
Latitude
Longitude
Altitude
0.00 m HAE (Height above ellipsoid)
Antenna:
Type
Zephyr Geodetic Model 2
Height (true vertical)
0.00 m
Measurement method
Bottom of antenna mount