Справочник Пользователя для Acer S5301WB

Скачать
Страница из 106
39
                                                                                                                     
Serial Number Upgrade SOP 
 
Hardware required 
1.  Standard RS232 Download cable 
2.  Personal computer or laptop computer 
 
Software required 
1.  Acer_Service_Tool(Data)_3.1.exe 
 
When need to use this Serial Number Upgrade program: 
    When it’s time to replace Main board for repair, it’s necessary to rewrite original S/N and 
some adjustment values into new Main board by the following process. 
 
Upgrade procedure 
1.  Prepare the download equipment: RS232 cable connect to PC and projector 
2.  Plug power cord into projector, and the projector will be in stand by mode. 
3.  Execute “Acer_Service_Tool(Data)_3.1.exe”, and it will appear as below picture. 
4.  Change to connected COM port and Click “Port Open” icon. 
 
 
5.  Read data from original Main board: 
Click  “Read  system  Data”,  and  it  will  read  the  Adjustment  data  (except  Auto 
keystone  data)  &  Serial  Number  from  projector  and  show  the  “Read  complete” 
message in information block. 
 
 
4-1. Change to 
connected COM Port 
number 
4-2. Click “Port 
Open” 
5-1. Click this icon to 
read all data 
5-2. Show “Read 
Complete!”