Справочник Пользователя для Acer S5301WB

Скачать
Страница из 106
89
                                                                                                                     
3.  PC Alignment Procedure 
Equipment: 
-
  Pattern generator (Chroma-2337) 
OSD Default value: 
Item 
Value 
Cal R Offset 
512 
Cal G Offset 
512 
Cal B Offset 
512 
Cal R Gain 
637 
Cal G Gain 
637 
Cal B Gain 
637 
YPbPr R Offset 
512 
YPbPr B Offset 
512 
Procedure: 
Gray Level: 
1.  Connect power, D-sub, into projector.   
2.  Change Timing and pattern of pattern generator: 
3.  Timing: 1024*768 @60Hz (XGA) 
4.  Pattern:  As  Figure1  {A  near  white  color  (240,240,240)  and  a  near  black 
color(16,16,16)} 
5.  Light on projector 
6.  Set user OSD values to default. 
7.  Enter factory mode. 
8.  Set Factory values to default. 
9.  Press “Calibration RGB” to let the black level to just distinguish, and the light output 
of white level to just max. 
10.  Check the 32 levels of gray. All steps must appear. 
11.  Calibrate Dsub_1 only .( Dsub_2 follows Dsub_1 )   
   
White-black pattern