Справочник Пользователя для Master Bilt TAF-48HDSA

Скачать
Страница из 2
NOTE: Cabinet designed for optimum performance in air-conditioned area at 75°F ambient and 55% relative humidity. 
 
All specifications subject to change without notice.
908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com
PLAN VIEW
SIDE VIEW
ELEVATION VIEW
��������������������
��������������������
��������������������
TAC/TAF SERIES
FOODSERVICE SOLID DOOR REACH-INS
TECHNICAL SPECIFICATIONS
LISTINGS
HOOKUP
BID SPECIFICATIONS
Item no. TAC-_____HDSA and/or Item no. 
TAF-_____HDSA.
Provide_______(         ) Medium Temp 
Foodservice Solid Door Reach-in(s), and/or 
_______(         ) Low Temp Foodservice Solid 
Door Reach-In(s). Master-Bilt model no(s). 
TAC-_____HDSA and/or TAF_____HDSA.
Cabinet to be constructed of stainless steel 
interior and exterior. TAF models will be 
equipped with an electronically controlled 
1197-5/07-web
©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.
TAC MODELS: Via plug in, 8 foot long, flexible 3 wire 14/3 cord    
 
with molded plug. 20 amp service is required for all models.
TAF-27HDSA: Via plug in, 8 foot long, flexible 3 wire 14/3 cord with  
 
molded plug. 15 amp service is recommended.
TAF-48HDSA: Hardwired
TAF-74HDSA: Hardwired with separate junction boxes for 115V and 
 
208- 230V and with a maximum 20 amp fuse. 
monitoring system as well as an automatic 
defrost with double failsafe override.
All models to have digital thermometer 
(built into electronic controller interface on 
TAF models), electric condensate evaporator, 
heavy-duty casters, three welded wire, gray 
epoxy-coated shelves per section. Doors will 
be self-closing with 90° hold-open feature, 
locking horizontal handles and door frame 
heater. 
The refrigeration system will be top 
mounted and self-contained using R-134a 
refrigerant in TAC models and R-404A in TAF 
models. The temperature range will be 34° 
to 41°F (1° to 5°C) for TAC models and 0° to 
-20°F (-18° to -29°C) for TAF models. 
Cabinet to have standard limited 4 year 
extended compressor warranty and 1 year 
limited parts and labor warranty. Cabinet to 
be UL, C-UL and NSF listed.
NEMA 5-20P
(TAC MODELS 
& TAF-27HDSA)
MODEL
DIMENSIONS
(in.)
DIMENSIONS
(mm)
VOLTS**
AMPS
UNIT
H.P.
NO. OF
DOORS
NO. OF 
SHELVES
STANDARD
SHELF SIZE
(in inches)
CAP.
CU. 
FT.
SHIP
CU. 
FT.
SHIP
WT.
LB/KG
L
D
H*
L
D
H*
MEDIUM TEMP
TAC-27HDSA
31
35
3
/
4
80
1
/
2
787
908 2045
115
12.1
1/2
1
3
25
1
/
4
 x 26
25.4
76.0 355/161
TAC-48HDSA
52
35
3
/
4
80
1
/
2
1321 908 2045
115
13.1
1/2
2
6
22
1
/
2
 x 26
45.9 119.0 465/211
TAC-74HDSA
78
35
3
/
4
80
1
/
2
1981 908 2045
115
15.0
3/4
3
9
22
1
/
2
 x 26
71.4 174.0 650/295
LOW TEMP
TAF-27HDSA
31
35
3
/
4
80
1
/
2
787
908 2045
115
10.5
3/4
1
3
25
1
/
4
 x 26
25.4
76.0 385/175
TAF-48HDSA
52
35
3
/
4
80
1
/
2
1321 908 2045 115/208-230
5.0/7.5
1
2
6
22
1
/
2
 x 26
45.9 119.0 540/245
TAF-74HDSA
78
35
3
/
4
80
1
/
2
1981 908 2045 115/208-230 6.2/11.2 1
1
/
2
3
9
22
1
/
2
 x 26
71.4 174.0 670/305
*Height includes casters. **TAF-48HDSA and TAF-74HDSA operate on a minimum of 208 volts. A voltage boosting transformer (part no. 39-01087) 