Справочник Пользователя для IBM Flex System V7000 Expansion Enclosure 4939H29

Модели
4939H29
Скачать
Страница из 610
Chapter 4. IBM Flex System V7000 Storage Node Initial Configuration 
153
Draft Document for Review January 29, 2013 12:52 pm
8068ch04-Initial Config.fm
4.1.6  Management interface planning
IBM PureFlex Systems are pre-configured, pre-integrated infrastructure systems with 
different management options:
��
Chassis Management Module (CMM)
��
Flex System Manager (FSM)
For information and the actual implementation of the management modules, refer to 
Implementing Systems Management of IBM PureFlex System, SG24-8060
Chassis Management Module (CMM)
The IBM Flex System Enterprise Chassis Management Module (CMM) is a hot-swap module 
that configures and manages all installed chassis components. The chassis comes with one 
Chassis Management Module in the CMM bays.
The IBM Flex System Chassis Management Module auto-detects and manages the hardware 
of the entire Flex chassis and provide centralized system monitoring and management. 
The IBM Flex System Manager Node (FSM)
The Flex System Manager (FSM) is an advanced chassis management appliance which 
provides the ability to manage up to four enterprise chassis. It is designed with a specialized 
compute node, storage, networking, and provides physical and virtual management 
capabilities.
The FSM appliance is based on an Intel-based x86 compute node that comes with preloaded 
management software. The FSM software contains a fully operational management stack for 
managing multiple chassis from a single focal-point for support of all assets and resources in 
IBM PureFlex Systems handling the complete range of management tasks. The following is a 
list of the tasks that can be performed from by the FSM:
��
Service requests
��
Incident handling and problem resolution
��
Handling specialized management tasks in connection with:
– Security 
– Performance 
– Resource allocation
– Application version control
4.2  Initial setup for IBM Flex System V7000 Storage Node
When a new IBM Flex System V7000 Storage Node control enclosure is installed in the Flex 
System chassis for the first-time you must create and configure it into 
clustered system
. The 
following procedure will guide you through the necessary steps to set up your IBM Flex 
System V7000 Storage Node system for the first time in this configuration.
Note: The IBM Flex System Chassis Management Module provides control and 
information on the storage hardware, while the IBM Flex System Manager in addition 