8068ch08-Storage Pools.fm
Draft Document for Review January 29, 2013 12:52 pm
300
 
IBM Flex System V7000 Storage Node Introduction and Implementation Guide
8.1.1  Actions on internal drives
There are a few actions that can be taken on internal drives when you select the drive and 
right-click it, or click the Actions drop-down menu (Figure 8-5). 
Figure 8-5   Take actions on internal drives
��
The Fix Error action starts the Directed Maintenance Procedure (DMP) for a defective 
drive. 
��
The internal drives can be taken offline when there are problems on the drives by clicking 
Take Offline in the Actions drop-down menu. A confirmation window opens (Figure 8-6). 
The IBM Flex System V7000 Storage Node storage system prevents the drive from being 
taken offline if there might be data loss as a result. A drive should be taken offline only if a 
spare drive is available.
Figure 8-6   Take Drive Offline warning window