Справочник Пользователя для IBM Flex System V7000 Expansion Enclosure 4939H29
Модели
4939H29
Chapter 1. Introduction to IBM Flex Systems and IBM PureSystems offerings
29
Draft Document for Review January 29, 2013 12:52 pm
8068ch01-Intro.fm
The FC3171 8Gb SAN Pass-thru can be configured using either command line or QuickTools.
Command Line: Access the module via the console port through the IBM Flex System
Chassis Management Module or through the Ethernet Port. This method requires a basic
understanding of the CLI commands.
Chassis Management Module or through the Ethernet Port. This method requires a basic
understanding of the CLI commands.
QuickTools: Requires a current version of the JRE on your workstation before pointing a
web browser to the modules IP address. The IP Address of the module must be
configured. QuickTools does not require a license and code is included.
web browser to the modules IP address. The IP Address of the module must be
configured. QuickTools does not require a license and code is included.
For more information about the IBM Flex System FC3171 8Gb SAN Pass-thru, refer to IBM
Flex System FC3171 8Gb SAN Switch and Pass-thru, TIPS0866.
Flex System FC3171 8Gb SAN Switch and Pass-thru, TIPS0866.
1.5.8 IBM Flex System IB6131 InfiniBand Switch
IBM Flex System IB6131 InfiniBand Switch is a 32 port InfiniBand switch. It has 18 FDR/QDR
(56/40 Gbps) external ports and 14 FDR/QDR (56/40 Gbps) internal ports for connections to
nodes. This switch ships standard with QDR and can be upgraded to FDR.
(56/40 Gbps) external ports and 14 FDR/QDR (56/40 Gbps) internal ports for connections to
nodes. This switch ships standard with QDR and can be upgraded to FDR.
Running the MLNX-OS, this switch has one external 1Gb management port and a mini USB
Serial port for updating software and debug use, along with InfiniBand internal and external
ports.
Serial port for updating software and debug use, along with InfiniBand internal and external
ports.
The switch has fourteen internal QDR links and eighteen CX4 uplink ports. All ports are
enabled. The switch can be upgraded to FDR speed (56 Gbps) via the Feature On Demand
(FOD) process.
enabled. The switch can be upgraded to FDR speed (56 Gbps) via the Feature On Demand
(FOD) process.
For more information about the IBM Flex System IB6131 InfiniBand Switch, refer to IBM Flex
System IB6131 InfiniBand Switch, TIPS0871.
System IB6131 InfiniBand Switch, TIPS0871.
1.6 Introduction to IBM Flex System storage
Either the IBM Storwize V7000 or IBM Flex System V7000 Storage Node is an integrated part
of the IBM PureFlex System depending on the model. Figure 1-15 on page 30 shows the IBM
Flex System V7000 Storage Node where the left controller, called a cannister, is taken out.
For the IBM Storwize V7000 products, the cannisters mounts from the rear where as in the
IBM Flex System V7000 Storage Node, the controllers mounts from the front.
of the IBM PureFlex System depending on the model. Figure 1-15 on page 30 shows the IBM
Flex System V7000 Storage Node where the left controller, called a cannister, is taken out.
For the IBM Storwize V7000 products, the cannisters mounts from the rear where as in the
IBM Flex System V7000 Storage Node, the controllers mounts from the front.
Note: Infiniband is not a supported protocol for IBM Flex System V7000 Storage Node or
the Storwize V7000.
the Storwize V7000.