Chapter 12. Host Configuration 
493
Draft Document for Review January 29, 2013 12:52 pm
8068ch12-Host Config.fm
12.3.3  Windows 2008 R2 FCoE volume attachment
The equipment we have for demonstrating volume attachment for an FCoE capable server is 
an IBM Flex System x240 Compute Node running Microsoft Windows 2008 R2 Enterprise, 
two IBM Flex System Fabric CN4093 10Gb Converged Scalable Switches and one IBM Flex 
System V7000 Storage Node. All is installed in a single IBM Flex System Enterprise Chassis.
To perform FCoE volume attachment in Windows 2008 R2 complete the following steps:
1. Configure connectivity between the host and the IBM Flex System V7000 Storage Node. 
This is done on the FCoE capable switches and includes configuring VLANs. For more 
information about how to configure VLANs on the CN4093 FCoE switches refer to 
Chapter 11, “SAN Connections and Configuration” on page 431.
2. Configure appropriate zoning for interconnecting the 10Gb FCoE host ports with the IBM 
Flex System V7000 Storage Node 10Gb FCoE ports. For more information about how to 
configure zoning on the CN4093 FCoE switches refer to  Chapter 11, “SAN Connections 
and Configuration” on page 431
.
3. On the IBM Flex System V7000 Storage Node click your Windows 2008 R2 FCoE host in 
the All Hosts view (Figure 5-37) and review that a volume is mapped to the host.
Figure 12-30 shows that a 200GB volume is mapped to our FCoE host.
Figure 12-30   Volumes by Host - 200GB volume mapped
You may also navigate to the Hosts screen, right-click your FCoE host and select 
Properties
 Mapped Volumes for the host. This screen displays which Fibre Channel 
ports are defined for the host. FCoE ports displays as if they were ordinary FC ports 
showing World Wide Names (WWNs) for the Host Bus Adapters (HBAs).
Figure 12-31 on page 494 shows the ports that are defined for the FCoE capable IBM Flex 
System x240 Compute Node.