Справочник Пользователя для Intel SSD DC S3500 300GB SSDSC2BB300G4

Модели
SSDSC2BB300G4
Скачать
Страница из 31
 
Intel® Solid-State Drive DC S3500 
April 2013 
Product Specification 
Order Number: 328860-001US   
11
 
2.5 
Product Regulatory Compliance 
Intel SSD DC S3500 meets or exceeds the regulatory or certification requirements 
in Table 13. 
Table 13. 
Product Regulatory Compliance Specifications  
Title 
Description 
Region For Which 
Conformity Declared 
TITLE 47-Telecommunications CHAPTER 1— FEDERAL 
COMMUNMICATIONS COMMISSION PART 15 — RADIO 
FREQUENCY DEVICES 
ICES-003, Issue 4 Interference-Causing Equipment   
Standard Digital Apparatus 
FCC Part 15B Class B 
 
CA/CSA-CEI/IEC CISPR 22:02. This is CISPR 
22:1997 with Canadian Modifications 
USA 
 
Canada 
IEC 55024 Information Technology Equipment — 
Immunity characteristics— Limits and methods of 
measurement CISPR24:2010 
EN-55024: 1998 and its amendments 
European Union 
IEC 55022 Information Technology Equipment — Radio 
disturbance Characteristics— Limits and methods of 
measurement CISPR24:2008 (Modified) 
EN-55022: 2006 and its amendments 
European Union 
EN-60950-1 2
nd
 Edition 
Information Technology Equipment — Safety 
— Part 1: General Requirements 
USA/Canada 
UL/CSA EN-60950-1 2
nd
 Edition 
Information Technology Equipment — Safety 
— Part 1: General Requirements 
USA/Canada 
 
2.6 
Reliability 
Intel SSD DC S3500 meets or exceeds SSD endurance and data retention requirements 
as specified in the JESD218 standard. Reliability specifications are listed in the table 
below: 
 
Table 14. 
Reliability Specifications 
Parameter 
Value 
Uncorrectable Bit Error Rate (UBER) 
< 1 sector per 10
17
 bits read 
 
Uncorrectable bit error rate will not exceed one sector in the 
specified number of bits read. In the unlikely event of a 
non-recoverable read error, the SSD will report it as a read failure to 
the host; the sector in error is considered corrupt and is not returned 
to the host. 
Mean Time Between Failures (MTBF) 
2,000,000 hours 
 
Mean Time Between Failures is estimated based on Telcordia* 
methodology and demonstrated through Reliability Demonstration 
Test (RDT). 
Power On/Off Cycles 
24 per day 
 
Power On/Off Cycles is defined as power being removed from the 
SSD, and then restored. Most host systems remove power from the 
SSD when entering suspend and hibernate as well as on a system 
shutdown.