Техническая Спецификация для Cisco Aironet 2602E AIR-SAP2602E-AK9-5
Модели
AIR-SAP2602E-AK9-5
© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 6 of 7
Item
Specification
Dimensions
(W x L x H)
(W x L x H)
●
Access point (without mounting bracket): 8.69x8.69x2.11in. (22.1x22.1x5.4)
Weight
●
2.3 lbs (1.04 kg) (2.7 lbs for external)
Environmental
Cisco Aironet 2600i
●
Nonoperating (storage) temperature: -22 to 158°F (-3 0 to 70°C)
●
Nonoperating (storage) Altitude Test 25˚C, 15,000 ft.
●
Operating temperature: 32 to 104°F (0 to 40°C)
●
Operating humidity: 10 to 90% percent (noncondensing)
●
Operating Altitude Test: 40˚C, 9843 ft.
Cisco Aironet 2600e
●
Nonoperating (storage) temperature: -22 to 158°F (-3 0 to 70°C)
●
Nonoperating (storage) Altitude Test: 25˚C, 15,000 ft.
●
Operating temperature: -4 to 131°F (-20 to 55°C)
●
Operating humidity: 10 to 90 % (noncondensing)
●
Operating Altitude Test: 40˚C, 9843 ft.
System Memory
●
256 MB DRAM
●
32 MB flash
Input Power
Requirements
Requirements
●
AP2600: 44 to 57 VDC
●
Power Supply and Power Injector: 100 to 240 VAC; 50 to 60 Hz
Powering Options
●
802.3af Ethernet Switch
●
Cisco AP2600 Power Injectors (AIR-PWRINJ4=)
●
Cisco AP2600 Local Power Supply (AIR-PWR-B=)
Power Draw
●
AP2600: 12.95W
Note: When deployed using Power over Ethernet (PoE), the power drawn from the power sourcing equipment will be
higher by some amount depending on the length of the interconnecting cable. This additional power may be as high as
2.45W, bringing the total system power draw (access point + cabling) to 15.4W.
higher by some amount depending on the length of the interconnecting cable. This additional power may be as high as
2.45W, bringing the total system power draw (access point + cabling) to 15.4W.
Warranty
Limited Lifetime Hardware Warranty
Compliance
Standards
Standards
◦
UL 60950-1
◦
CAN/CSA-C22.2 No. 60950-1
◦
UL 2043
◦
IEC 60950-1
◦
EN 60950-1
◦
EN 50155
●
Radio approvals:
◦
FCC Part 15.247, 15.407
◦
RSS-210 (Canada)
◦
EN 300.328, EN 301.893 (Europe)
◦
ARIB-STD 66 (Japan)
◦
ARIB-STD T71 (Japan)
◦
EMI and susceptibility (Class B)
◦
FCC Part 15.107 and 15.109
◦
ICES-003 (Canada)
◦
VCCI (Japan)
◦
EN 301.489-1 and -17 (Europe)
◦
EN 60601-1-2 EMC requirements for the Medical Directive 93/42/EEC
●
IEEE Standard:
◦
IEEE 802.11a/b/g, IEEE 802.11n, IEEE 802.11h, IEEE 802.11d
●
Security:
◦
802.11i, Wi-Fi Protected Access 2 (WPA2), WPA
◦
802.1X
◦
Advanced Encryption Standards (AES), Temporal Key Integrity Protocol (TKIP)
●
EAP Type(s):
◦
Extensible Authentication Protocol-Transport Layer Security (EAP-TLS)
◦
EAP-Tunneled TLS (TTLS) or Microsoft Challenge Handshake Authentication Protocol Version 2 (MSCHAPv2)